Nukote BM-GT

DESCRIPTION:

NUKOTE BM-GT® is NCSI’s high performance polyurea designed and developed to perform well in conjunction with approved woven and non-woven geotextile fabrics in various applications. Nukote BM-GT is a two-component, 100% solids, and low shrinkage pure polyurea with very high elongation. It is suitable to be used as composite membrane with geotextile fabrics. Nukote BM-GT is hydrophobic and eliminates moisture problems that commonly cause pin holing and blistering in most polyurethane, polyurethane-hybrid and other organic coating systems when spraying over a fabric on damp soil. This aromatic polyurea elastomer displays good chemical resistance, thermal stability and UV resistance and good moisture permeation resistance Nukote BM-GT also performs well as a standalone membrane with excellent adhesion to most properly primed substrates.

FEATURES:

  • 100% solids with zero VOC
  • Fast reactivity and cure time resulting in almost immediate return-to-service time
  • Performs in constant process temperatures from -40 °F to 250 °F (-40 °C to 120 °C)
  • Maintains high physical properties on weathering
  • Superior elongation and tear properties
  • Seamless, resilient, flexible and durable
  • Excellent corrosion protection
  • High impact and abrasion resistance
  • Continuous thermal stability
  • Resistant to many solvents, acids and alkalis (consult NCSI)
  • Low permeability waterproofing membrane

TYPICAL USES:

  • Industrial and commercial waterproofing
  • Below grade waterproofing, damp proofing
  • Secondary containment, bund lining –waterproofing and sealing
  • Pre-formed tank pads
  • Roofing and rehabilitation of old roofing with geotextile fabrics
  • Upgrading of old bituminous roofs and asphalt bund lining
  • Landfill containment.

COLORS:

Standard medium grey only. Custom colors, blended to match any RAL number, are available upon request subject to minimum quantity.

PACKAGING:

100-gallon (380-liter) drum sets, shipped in metal drums of 50 gallons (190 liters) each of side A and side B

10-gallon (38-liter) kits, shipped in plastic pails of 5 gallons (19 liters) each of side A and side B

275-gallon (1045 liter) totes.

COVERAGE:

Nukote BM-GT may be applied at any rate to achieve the desired thickness. Calculation for theoretical coverage: 40 Ft² /gal @ 40 mils (1 m²/liter @ 1mm).

STORAGE:

Twelve to eighteen months in factory delivered, unopened drums. Store on pallets and keep away from extreme heat, freezing, and moisture. The use of drum heaters is encouraged to reduce material viscosity at low temperatures.

TECHNICAL DATA (All values @ 77 ºF / 25 ºC) US Metric
Solids by volume (ASTM D2697) 100% 100%
Volatile organic compounds (ASTM D2369) 0 lb./gal 0 gm/ lit
Theoretical coverage 40 ft²/gal @ 40 mils 1m²/ lit @ 1mm
Specific Gravity of materials (ASTM D792) A: 9.35, B: 8.43 lbs./gal A: 1.12, B: 1.01 kg/ liter
Viscosity at 158 ºF/70 ºC in cps ±10% (ASTM D4878) A-60, B-60 A-60, B-60
Shelf life @ 77 ºF /25 ºC 12 to 18 Months 12 to 18 Months
Tensile strength (ASTM D412-C) 2800 to 3200 psi 20 to 23 MPa
Elongation (ASTM D412-C) 500-600 % 500-600 %
Hardness (ASTM D2240) 80 to 85 Shore A 80 to 85 Shore A
Flexibility (2mm mandrel ASTM D522) Pass Pass
Water vapour transmission rate (ASTM E96) 0.040-0.042grains/hr-ft² 0.25 to 0.35gms/hr-m²
Water absorption -24 hours (ASTM D570) ~ 1. % ~1%
Crack Bridging @ -13 ºF/-25 ºC (ASTM C1305), 25 cycles Pass Pass
Tear strength (ASTM D642 ) 450 to 500 pli 75 to 85 Kn/m
Impact Resistance (ASTM G14), No Holidays > 200 in-lbf > 20 J (N-m)
Fire Rating (ASTM E108) Meets Class A for Flame spread
Flash point Pensky Martin >200 °F >93 °C
Service temperature (Dry) -40 °F to 250 °F -40 °C to 120 °C
Abrasion Resistance (ASTM D4060) weight loss < 30 mg loss Taber CS 17 wheel 1Kg/1000 rev
PROCESSING PROPERTIES (Under standard lab conditions)
Mix Ratio V/V 1:1
Gel time 6 to 20 seconds
Tack free time ( DFT & Temperature dependent) 30 to 45 Seconds
Post cure time 24 hours
Properties and values are highly dependent on equipment, spray gun, mix chamber temperature, pressure and related parameters. Variations are possible and expected. Values included above are per NCSI standard lab practices & methodology at various dry film thicknesses

MIXING:

Nukote BM-GT might not be diluted under any circumstance. Thoroughly mix Nukote BM-GT Part B resin material with air driven power equipment until a homogeneous mixture and color is obtained. Always use dedicated spray equipment.

SURFACE PREPARATION:

Concrete:

The surface of a concrete subfloor should be dry, smooth, structurally sound and free of depression, scale, or foreign deposits of any kind. Remove all curing compounds. Abrasive blast, sweep blast or water blast to remove all latent material and expose voids. Use a good quality epoxy filler or mortar for void and spall filling, skim coat or repairs. Prime, fill imperfections in the substrate surface to limit out-gassing. All concrete substrates, on or below grade level should be tested for moisture content. On-grade or below-grade concrete floors or slabs should have a moisture barrier installed to protect from ground moisture. The surface preparation of concrete should meet and conform to Joint NACE
6/SSPC-SP 13 standards and achieve a concrete surface profile of CSP 3 to CSP 6 as per ICRI Guideline No.03732 for optimum performance.

Metal:

All surfaces should be clean and free from contamination. The surface should be assessed and treated in accordance with ISO 8504, Abrasive blast the surface to minimum NACE-2/SSPCSP-10/Sa 2.5, as per ISO 8501-1, for a visual assessment of surface cleanliness with an anchor profile of 3 to 4 mils (75 -100 microns). Soluble salts must be removed to an acceptable levels. Refer to NCSI surface preparation manual for detailed procedures for different types of substrates.

APPLICATION:

Must be applied utilizing high-pressure, heated plural component spray proportioning equipment, such as Graco Reactor 2, or equivalent, capable of delivering materials without loss of pressure or drop in temperature for the appropriate hose length on a consistent basis. For optimum performance, the substrate should be abrasive blasted. Concrete substrates should be allowed to cure a minimum of 30 days. On concrete, Nukote BM-GT should always be applied over a suitable primer for maximum adhesion. For all submersed or immersion applications, use of a suitable primer is absolutely essential. On horizontal surface applications, a texture “stipple” coat can be applied for non-skid purposes, after reaching the initial desired film thickness. Recommended DFTs are a function of the project specific requirements. Please review your specific project with Nukote technicians.

EQUIPMENT CLEAN UP:

Cured product may be disposed of without restriction. Uncured Isocyanate and resin portions should be mixed together and disposed of in accordance with local regulations. Containers should be disposed of according to local environmental laws and ordinances.

LIMITATIONS:

Do not open until ready to use, and store in a sealed container after opening. Adding a nitrogen blanket is strongly recommended for the ‘A’ component when storing after opening.

WARNING:

This product contains Isocyanate and curatives

CHEMICAL RESISTANCE:

Each Nukote product formulation has varying levels of resistance to specific chemicals. Please review the chemical immersion test data included in the Nukote Test Book for general resistance to specific chemicals at specific concentration levels. Chemical concentrations are complex and when combined with temperatures above ambient levels this complexity increases exponentially. Contact Nukote Technical Personnel for specific recommendations for chemical resistance prior to specifying these products in this application type. Consult with NCSI for more details on product and chemical resistance. The following chart is the results of Polyurea immersed in chemicals and tested as per modified ASTM D 3912.

Chemicals Resistance
Hydrochloric acid upto 10% R
Sulphuric Acid 15% R
Phosporic Acid 10% R
Acetic Acid 10% R
Sea water R
Waste Water R
Water @ 176 ºF (80 ºC) R
Hydrogen Sulphide (gas) R
Sodium Hydroxide-50% RC
Ammonium Hydroxide 20% R
Ammonium Hydroxide 50% RC
Pottasium Hydroxide 10% R
Pottasium Hydroxide 20% RC
Sodium Hydroxide 20% R
De ionized Water R
Diesel Fuel, Gasoline (unleaded) R
Motor Oil, Brake Oil RC
Hydraulic Oil R
R = Resistant, RC = Slight surface change or discolouration with no loss of hardness

Download documents

tds

Nukote BM-GT TDS
tds document

WARRANTIES AND DISCLAIMERS:

Nukote Coating Systems International, a Nevada, USA Corporation warrants that the two components of this product shall conform to the technical specifications published in the product literature. The quality and fitness of the product is dependent upon the proper mixture and application of the components by the applicator. Nukote Coating Systems has no role in the application of the finished polymer other than to manufacture and supply its two components. It is vital that the person applying this product understands the product and is fully trained and certified in the use of plural component equipment and application of plural component materials. There are no warranties that extend beyond the description on the face of this instrument, except when provided in writing, directly by Nukote Coating Systems International and executed under seal by a company officer.

Note:

NUKOTE COATING SYSTEMS INTERNATIONAL maintains a vast library of technical and marketing data for use by our staff, affiliated companies and key clients.

If you are not an NCSI staff member or contract affiliate and wish to access the data, please send us a request form and we will revert within 48-hours.

Our product range is derived from our proprietary and/or patented chemical formulations. We formulate products specific to application requirements modifying the products properties to improve and enhance performance in a variety of variable conditions, including abrasion resistance, chemical resistance, saltwater resistance, impact resistance, ultraviolet exposures, and so on. This provides our clients with unique solutions to their specific requirements and allows us to provide products designed specifically for oil and gas, construction, infrastructure, power generation and even entertainment industries.

The products represented below do not comprise the full breadth of our range of products but are limited to the most commonly specified formulations in our range. Many of our products are defined to exact requirements of a manufacturer or end-user and are thus not included in our electronically published data. Please click on the link below to access the data sheets incorporated into this site. For specific questions regarding product selection contact us directly at any of our regional locations.