Nukote Polyprime II

Description:

Nukote Polyprime II is a two component 1:1 ratio, rapid setting, low temperature curing liquid applied, aromatic urethane polyurea primer suitable for metal substrates. Nukote Polyprime II is easy to apply, sets quickly, and has excellent physical properties. It can also be used in concrete, and masonry

Features:

  • Very high solids
  • Non Toxic
  • Fast setting
  • Odorless
  • Chemical resistance
  • Low temperature curing -10 °F (-12 ºC)
  • Remains Flexible in Wide Range of Temperatures

Typical uses:

Low temperature and rapid cure primer for metal and other substrates

Colors:

Standard color is Black. A clear amber and gray are also available upon request subject to minimum quantity.

Packaging:

100-gallon (380-liter) drum sets, shipped in metal drums of 50 gallons (190 liters) each of side A and side B

10-gallon (38-liter) kits, shipped in plastic pails of 5 gallons (19 liters) each of side A and side B 275-gallon (1045 liter) totes.

Coverage:

Nukote Polyprime II spread rate is 400 ft²/ gal at 4 mils (9.9 m²/liter at 100 microns) thickness without factoring any loss

Storage:

Twelve to fifteen months in factory delivered, unopened drums. Store on pallets and keep away from extreme heat, freezing, and moisture.

Mixing:

Nukote Polyprime II might not be diluted under any circumstance. Polyprime II should be applied using a 1:1 heated proportioning dispensing system Product should be Pre conditioned to 80 ºF (27 ºC)

Limitations:

Do not open until ready to use, and store in a sealed container after opening. Containers that have been opened must be used as soon as possible. Surfaces must be dry, clean and free of foreign matter. Not UV stable. Will discolour in exterior applications

TECHNICAL DATA (All values @ 77 ºF / 25 ºC) US Metric
Solids by volume (ASTM D2697) 99% 99%
Volatile organic compounds (ASTM D2369) 0.12lb./gal 5 gm/ lit
Theoretical coverage) 400 ft²/gal @ 4 mils) 10m²/ lit @ 100 microns
Specific Gravity of materials (ASTM D792) A: 9.21, B: 7.85 lbs./gal A:1.106, B:0.94kg/ liter
Viscosity at 77 ºF /25 ºC in cps ±10% (ASTM D4878) A-20, B-20 A-20, B-20
Shelf life @ 77 ºF /25 ºC 12 – 15 Months 12-15 Months
Flash point Pensky Martin >150 ºF > 66 ºC
Hardness (ASTM D 2240) 65-75 65-75
Tensile Strength (ASTM D 412) 3600-4400 Psi 25-30 Mpa
Elongation ASTM D 412 7% 7%
PROCESSING PROPERTIES (Under standard lab conditions)
Mix Ratio V/V 1:1
Pot Life 2 to 3 minutes
Tack Free 5-10 minutes
Maximum Recoat time 20-30 minutes
Properties and values are highly dependent on equipment, spray gun, mix chamber temperature, pressure and related parameters. Variations are possible and expected.

Surface preparation:

Metal:

All surfaces should be clean and free from contamination. The surface should be assessed and treated in accordance with ISO 8504, Abrasive blast the surface to minimum NACE-2/SSPC SP-10/Sa 2.5, as per ISO 8501-1, for a visual assessment of surface cleanliness with an anchor profile of 3 to 4 mils (75 -100 microns). Soluble salts must be removed to an acceptable levels. Refer to NCSI surface preparation manual for detailed procedures for different types of substrates.

Concrete

The surface of a concrete subfloor should be dry, smooth, structurally sound and free of depression, scale, or foreign deposits of any kind. Remove all curing compounds. Abrasive blast, sweep blast or water blast to remove all latent material and expose voids. Use a good quality epoxy filler or mortar for void and spall filling, skim coat or repairs. Prime, fill imperfections in the substrate surface to limit out-gassing. All concrete substrates, on or below grade level should be tested for moisture content. On-grade or below-grade concrete floors or slabs should have a moisture barrier installed to protect from ground moisture. The surface preparation of concrete should meet and conform to Joint NACE 6/SSPC-SP 13 standards and achieve a concrete surface profile of CSP 3 to CSP 6 as per ICRI Guideline No.03732 for optimum performance.

Application:

Must be applied utilizing a 1:1 proportioning dispensing system or an airless spray system with a static mixer. Allow primer to be tack free 5-10) minutes before over coating. The product is suitable for application in extreme cold weather 10 °F (-12 °C).

Equipment clean up:

Cured product may be disposed of without restriction. Uncured Isocyanate and resin portions should be mixed together and disposed of in accordance with local regulations. Containers should be disposed of according to local environmental laws and ordinances.

Nukote Polyprime II is difficult to clean up after it has cured. Equipment should be cleaned with environmentally safe solvent, as permitted under local regulations, immediately after use.

Limitations:

Do not open until ready to use, and store in a sealed container after opening. Containers that have been opened must be used as soon as possible. Surfaces must be dry, clean and free of foreign matter. Not UV stable. Will discolour in exterior applications.

Warning:

This product contains Isocyanate and solvent.

Warranties and disclaimers:

Nukote Coating Systems International, a Nevada, USA Corporation warrants that the two components of this product shall conform to the technical specifications published in the product literature. The quality and fitness of the product is dependent upon the proper mixture and application of the components by the applicator. Nukote Coating Systems has no role in the application of the finished polymer other than to manufacture and supply its two components. It is vital that the person applying this product understands the product and is fully trained and certified in the use of plural component equipment and application of plural component materials. There are no warranties that extend beyond the description on the face of this instrument, except when provided in writing, directly by Nukote Coating Systems International and executed under seal by a company officer.

Download documents

WARRANTIES AND DISCLAIMERS:

Nukote Coating Systems International, a Nevada, USA Corporation warrants that the two components of this product shall conform to the technical specifications published in the product literature. The quality and fitness of the product is dependent upon the proper mixture and application of the components by the applicator. Nukote Coating Systems has no role in the application of the finished polymer other than to manufacture and supply its two components. It is vital that the person applying this product understands the product and is fully trained and certified in the use of plural component equipment and application of plural component materials. There are no warranties that extend beyond the description on the face of this instrument, except when provided in writing, directly by Nukote Coating Systems International and executed under seal by a company officer.

Note:

NUKOTE COATING SYSTEMS INTERNATIONAL maintains a vast library of technical and marketing data for use by our staff, affiliated companies and key clients.

If you are not an NCSI staff member or contract affiliate and wish to access the data, please send us a request form and we will revert within 48-hours.

Our product range is derived from our proprietary and/or patented chemical formulations. We formulate products specific to application requirements modifying the products properties to improve and enhance performance in a variety of variable conditions, including abrasion resistance, chemical resistance, saltwater resistance, impact resistance, ultraviolet exposures, and so on. This provides our clients with unique solutions to their specific requirements and allows us to provide products designed specifically for oil and gas, construction, infrastructure, power generation and even entertainment industries.

The products represented below do not comprise the full breadth of our range of products but are limited to the most commonly specified formulations in our range. Many of our products are defined to exact requirements of a manufacturer or end-user and are thus not included in our electronically published data. Please click on the link below to access the data sheets incorporated into this site. For specific questions regarding product selection contact us directly at any of our regional locations.